pool timer trippers not working

pool timer trippers not working

220V clocks have 5 terminals, 110V clocks have 3 terminals. You dont have two OFF trippers, right? Some white lithium grease on the switch can help in some cases. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. This is the first step to confirm if there is power or not. It could also be loose wires, either on the time clock terminal board, or on the timer motor. It started lagging again a week or so ago. I called Intermatic and there is nothing you can do except check it every time you have a power loss. Thanks again for your help. You may notice that the time pointer is loose or is moving around too much.If you find your pointer is loose, simply tighten the screw that holds the timer in place so that it doesnt wiggle around. Just installed a new timer. (usually not). In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. You need extreme care in this next step. I tried to change the on tripper due to Daylight savings time & dropped the screw. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. "author": {
Is power reaching the time clock? Put them back on and tighten them. I have an intermatic T20004R and my timer is working because it is keeping the correct time. Hi Matthew T104 can only turn one pump on and off. Here are some pictures. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. It is a mechanical issue between the trippers and the switch lever. The timer switch has a solid click between trying to turn it on and off but since no power is going to the timer I get no juice tot he motor. No matter what caused the issue, there is typically an easy fix! My timer clock does not run and the manual on off switch does not turn off the pump motor. Timer not tripping pump on. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. A switch is easier to use, so you dont have to open the clock and stick wet fingers in there, and using the breaker is also less than desirable, as they can wear out faster if used as a switch. Today is the second day that I have had to turn it on manually. Clean the gears with a toothbrush if you see debris or gunk in them. If none of the above suggestions resolves your issues or the issues continue to persist, it may be a good idea to purchase a new Intermatic timer for your pump. I just replaced my T101 timer 2 years ago. Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). This product is certified by Amazon to work with Alexa. Intermatic 156T1978A Timer Switch Trippers, Intermatic Timer Parts Replacement for T100 Series and Intermatic Time Clocks T101, T102, T103, T104, Pool Timer On Off Clips(4 ON / 4 Off / 8 Screws) : Amazon.com.au: Home Improvement Or the switch can suffer wear over many years, and might not make solid contact. 110V or 220V? To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. HI Ben, yes just remove the OFF tripper, and the clock will always be ON. Hi Tom, sure you can spray some 3-in-1 or wd-40 on the motor gears, just depress the tab at 12 oclock and pop out the mechanism, to target the oil onto the gears. Just some ideas. 120Volt Tork 1101 timers can be fixed with repair parts. If you find no answers readily apparent, then replace the timer mechanism they dont last forever! "primaryImageOfPage": {
I hope this helps. Now Im having to turn my pool pump on and off manually. Pool pump comes on fine with the on dog, but wont turn off. Hi Jerry, it could be that the lubricant is gone, or needs more lube on the switch. Intermatic timers are a great addition to your pool set up but they can go wrong. Check that the TEST button has not popped out. Take them off and inspect them and look for twists in them. If its not, it wont work properly. The gears in mechanical timers can get damaged. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 i have a P1121 intermatic timer connected to a hayward above ground pool pump. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. Beverly, it could be, but the cost of running wiring to the garage may be more than replacing it every 15-20 years. When I put the new one on, the trippers do not work. The timer not working is for the pump. First you want to make sure there is actually power getting from the power board to the timer itself. Hi, hope you are doing well. This div height required for enabling the sticky sidebar. Sound right? It should loosen up after a few goes when the grease and gunt dissolve. {
You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. i have an oval pool that is closed for the winter but there ha been a problem. Hi Rich, is one of those wires (white?) The terminals on the wires aren't tight. Analog timers are the simplest type of pool pump timer and are easy to use (and the cheapest). I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
If moving that is difficult, you could just avoid using the switch and turn the pump off with the timeclock instead, always keeping the switch on, and maybe taping the switch, to remind people not to use the switch. Inside, the 1 gear on the right side can be removed to access a metal bar. Also, once it reaches the tripper, the gears in the window no longer move. Welcome to Pool Spa Outpost! It stays on until I turn off the circuit breaker. I have a white, red, and black wire coming from the power source. You can replace it but its really just easier to replace the entire mechanism. Sometimes bugs get in there and jam the gears, sometimes debris is the issue and other times the gears get old and may lose a tooth. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. I had to order new trippers as mine have been straightened too many times. Any advice? Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. "description": "Frequently asked questions about Intermatic T104 and T101 timeclocks, used to power many loads, and the primary timer used for swimming pool pumps in America. We are on our third timer. Breakers go bad sometimes, after many years. Is that a faulty motor? I took the electrical box cover off and check the breaker connections. A power surge may have taken out the timer or the pump. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. Confused. Read full answer 2/14/2023 3:20:07 AM the ground wire? Any ideas? Tighten down all brass screws securely, to hold all wires firmly in place. Luis, it will, until it is switched to OFF, or until the OFF tripper shuts it off. Watch these tips and tricks before replacing it. If power is reaching the clock, and the gears are turning, but the dial is not turning this means the gear on the back of the dial is not engaged. when the lever is in the off position the gears stop turningis this unit wired incorrectly, Natural goes to A Rich. If you are not sure if your timer is working or not you will first need to know if its even operational. Thanks. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. I looked to see if the gears on the timer are running. Flip off the breaker. 2303 RR 620 S #135-378 Lakeway TX 78734 USA (737)-210-8494 Sign in or Register Compare Gift Certificates Advanced Search Search Keyword Required Categories Automatically search sub categories Brands Search By Price Price Range From to Search By Setting You will first want to look at the pool timer and see if you have two timer pins. Pop-in a new timer mechanism, and replace the wires to the previous configuration. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. When you flip the switch does it separate and reconnect the tabs? The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years. Replace the gears if this is an issue. We may earn a small commission. The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. The problem was the connections I made inside my main electrical panel, I used romex wire nuts to attach the solid core #10 wire that I used to hook up the timer to the existing stranded #10 wire and it didnt make the connection so to speak. Sometimes during power surges or lightning, these will be fused together and not come apart. If it continues and cant find solution, suggest replacing timer motor, or entire mechanism. DEWENWILS Pool Pump Timer, Digital Timer Box, 2HP 40A 120-277 VAC, 7-Day 20 ON/Off Programmable Timer Switch for Water . The works fine and keeps time while it is on but the second it turns the filter off, it stops keeping time and the cogs stop moving. The problem lies, where the power dies, as they say, Thanks for the response. Turn on / off manually work fine, but The clock gears still not moving. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . Basically youre eliminating possibilities until you find the cause. At some time the timer was disconnected and the pump wired direct to the breakers. The clock will also be missing 3-hours of time, so will need to be reset to the current time. Thanks in advance! There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. please help me. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. We have a comprehensive article that covers what to do when the pump circuit breaker continually trips. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Then after a bit, the pump restarts. Thank you so much. You most likely just need to now set the pins and the clock and your timer will work. PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Hi, I got the same problem as my clock not working. However, intermittently after the ON tripper switches pump on the pump will stop. Gold OFF tripper works for all models. The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. How about the GFCI outlet TEST button, is it tripped? Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Tracing the power it goes from breaker to control panel, and then to the time clock, then to the pump. Is it possible to do this by loosening the timer screw a bit? Partially loosen the screw that holds the "off" pin in place. Thanks in advanced. "width": "611",
Voltage is 243, frequency is 60hz. They are little ants that just came. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. Sometimes those are looped back to the control box. Once you do some you will want to re-tighten the hold down screw on the timer pin so it stays in place. Step 3 Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. After a few days its off by 6 or 7 hrs but still turns on and off fine any suggestions? Help! How can I fix this? You can replace the timer motor only, or the entire clock, both fairly easy to swap out. "publisher": {
Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear. First, verify the power is turned off at the breaker panel. Only perform this step if you are qualified. Check that the breaker is firmly pushed onto the bar, and is not loose. Articles and resources for swimming pool owners and DIYers. The circuit is protected by two ganged breakers.
Check out our online selection of new Intermatic timer clocks at InTheSwim.com! Basically 12 real life hours equals about 14 on the timer. I looked through the visual motor check and the gear still moving fine. The time does not advance after resetting. What happened? },
Any help is greatly appreciated. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Jul 20, 2021. After I replaced the motor with a 60Hz 277/208v motor the timer ran, but gained 1 hr/day. The pump worked perfectly before I unscrewed it. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. Or there could be a bad relay in the control panel, if you have ice cube style relays. Yes, likely a short to ground. Align the bar with the current time and push it back into place. You can replace the entire mechanism or the gears. It just seems to have a weak start?? Did the power recently go out or has the circuit breaker tripped? This morning the customer said it wasn't turning off. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. charging for timer($150.00) and filter cartridge replacement ($90.00) and a gasket($25.00)called bc of a hose leak, assume that is the gasket but then told that the other 2 parts are needed. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. The clock not turning on your Intermatic pool timer is a common issue. Or one of the wires may have broken, or lost the protective plastic insulation. Followed all directions and even watched YouTube troubleshooting videos. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. Hi Ryan, that sounds like a bad motor or a broken gear, you can replace just the motor, or the entire clock mechanism. I have changed the dog tripper and that does not take care of - Answered by a verified Electrician . Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. i would like to use a timer but am now afraid to try another. Perhaps you had a power outage during the night? Hi Davy, We had a storm last week and the yard flooded my pool so I went and switched the pool off at the breaker so it would not come on with the tabs until we were able to handle the pool. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. This pool timer is waterproof, heavy-duty, and accurate. not sure what is the problem. Hi, then the power for the clock must be from the switch, and not from the breaker? the problem lies, where the power dies as they say. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. Could be small bugs, or dirt, or both causing the problem. Now, Im going to order some additional timer clips. These clocks determine when your pool pump turns on, and how long it runs. Sometimes old power wires split or short-out. Phil. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. Check that dial is not warped. The trippers can also get damaged. "logo": {
Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 Do you have an answer to why my pump wont turn off or on? Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. I also dont see any ants or other insects. I turned the breaker off and back on and still not working. But of the timer itself is bad you will need a licensed electrician to change the timer for you. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. Theres power to the pump using the manual override. The pool timers I have had down there . the timer was directly plugged into a gfci and the pump directly into the timer. For additional tripper pairs on CLOCK-DIALorder 156T1978A. My timer runs, then after it reaches the off tripper, it stops, and never goes past the off tripper. Use Green ON tripper for T100 Series timers and the silver ON tripper is for all other models. And when switched on, power to the load terminals? "height": "219",
Or may be bent and not come together. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. Leave the paper inside your timer box so that you do not mistakenly misplace it. Hello have a question some what related. The most common pool timer used for inground pool pumps is the Intermatic time clock. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Also check that the motor number is compatible with your clock model. If I manually flip the switch nothing happens. Pool pump timers can last up to 20 years, depending on the model. Just moved into my house and the pool pump continues to run even after tripping the timer mechanism. Is the timer repairable, or should I just install a new one? on two occasions the plug from the pump almost melted and the second time the pool pump plug had to be replaced and i discontinued using the timer and disposed of it. Is the ON tripper all the way pushed onto the dial? Hi, Hi Dave, my pool timers not working but when I look in the little window I do see the largest back gear turning (possibly the yellow time plate gear as that appears to be moving..yet not keeping correct time.) If so, is there power coming into the clock (on the line terminals)? There is a switch control panel and replaced the 20amps DP switch as well. After a power failure the timer clock can start up backwards, mine has done this several times. Thank you. This will disengage the dial from the . Once you have the timer set to the correct time you then can loose the little hold down screw on both the timer on and timer off pins. It worked for a day but the day after it didnt work. T104 mechanisms (without the box) are cheaper than buying the mech + box, but if your box is old with rusty hinges, missing gaskets, latch that wont work, it may be best to replace the box as well. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. See the next section in this article for that. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Still no luck. Wont power on pump but can hear timer clicking away. Any other thoughts? The trippers will "trip" the analog clock to turn on and off automatically at the set times. You can also apply some of the troubleshooting steps to other brand timers. You off course will want to adjust one time pin at a time. Pool Timer Not Turning ON or OFF!! It is still moving and it will trip off but not on. Should it still not work, I suspect a motor failure for the clock. If not, Turn off breaker, release the mechanism with the tab on the inside top, to drop the mechanism forward. Look into the visual motor check window, near the top of the timer mechanism. That should quiet it down. If I have to tell you which terminals to measure, you shouldnt be doing this! If all looks tight and no foreign objects or insects are found to be in there, and the switch mechanism does not look worn (the silver part next to the tab you manually flip to turn on/off), then its probably a failing timer motor. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol!